Welcome to the Summary Page which describes the major New Features added to the Central Station Monitoring module within the MKMSCS STARK Version 5.1.35.XXXX Release.

 

HelpFilesStark

 

This New Features Table contains three columns of data relating to each of these New features:

1.Program Module(s) Affected - This column lists the specific modules that were improved.

2.Chapter Links - This column lists of the link(s) to the chapter(s) where the previous instructions, illustrations and explanations have been revised to reflect the program changes and/or enhancements.

3.Description of the Enhancement - A brief explanation of the new features, functions and enhancements that have been added in this release with links to all of the affected chapters and some related chapters, also.

 

This is the list (in the chart below) of features that were changed or enhanced specifically for MKMSCS.

 

Understanding the New features Chart:

All of the Program Module(s) that are Affected are listed.

The Chapter Links are provided for finding the instructions, illustrations, and details on the operation and usage of the new feature(s).

A brief Description of the Enhancement is shown, sometimes with additional Chapter Links.

 

Program Module(s) Affected

Chapter Links

Description of the Enhancement

 

 

 

MKMS STARK

Millennium Series User Interface

A special MKGM.dup file is included in this upgrade to enable the use of Google Maps® without incurring the map views limitation. Google Map® may now initially display either in the "roadmap" (default) view, or in the "satellite" view, as your Company's Central Station and/or Operations Manager prefers.

For those who want to use this feature, this feature requires the installation of a new Company Setting which may be accomplished by using the dbisql utility to run this script:

INSERT INTO "DBA"."CompanySettings"("Section","SettingName","SettingValue") 

VALUES('Feature','DefaultMapType','roadmap')

To change the default map display to "satellite":

update dba.companysettings set settingvalue = 'satellite' 

where settingname = 'DefaultMapType'

MKMS STARK

Employees

The Insert, Delete, and Left and Right Arrow Navigation Keys on your keyboard; plus the Ctrl+S combination (for Save) have been implemented on the Employees Form.

 

 


Central Station

Accounts Receivable

F2 - Subscriber Search

A new "Panel Description" Search By option has been added to the F2 - Subscriber Search function [and the Search button on the Sub Info (F2) Form within MKMSCS).

This new  "Panel Description" Search By option is associated with the Description that is defined in the Subscriber Panels section of the Monitoring Information tab within the Edit View of the Subscribers Form.

 

Columns

A User may now Select which specific columns are to be listed in the Search dialog:

i.Click the asterisk (¬) at the left of the list's Header row (see the mouse pointer in the illustration above) to display a list of all of the column names - and associated data - which may be displayed.

ii.By default, all Column Names will be Checked.

iii.Remove the Check mark (Click on the Check to remove it) to hide that column of data from the list.

 

A User may now Rearrange the left to right sequence in which the Columns are to be displayed:

i.To move a Column left or right of its original location, Drag and Drop that Column to the desired location.

ii.This relocation may be executed on the Vendor Search dialog itself, or within the Column List described above.

Central Station Monitoring

Create Mass Accounts

Account Templates

The Create Mass Accounts Form and Account Templates Forms has been updated with the current standard Navigation, Ribbon Menu systems, and also follows the selected Theme.

Central Station Monitoring

Dealer Users

The Dealers section of the Dealer Users dialog has been enhanced to allow the Dealer User to also be assigned to a Sub Dealer

The system assigned Telephone and Contact information will reflect the Dealer's unless a Sub Dealer is assigned, in which case that Telephone and Contact information will be the Sub Dealers'

Central Station Monitoring

On Test (F5)

Place an Account on Test

Add New Account

The Add New Account dialog - accessible using the On Test (F5) in MKMSCS and/or Place an Account on Test in MKMS - will now store certain User selections (i.e., Salesman. Town Code, Communicator Format, Alarm Group) as the defaults for those fields (any default may be reset by making a different selection).

Central Station Monitoring

CSID Zones

If a duplicate Signal ID and Physical Zone combination is entered in the CSID Zones tab in the Subscriber Panels section, a much more informative error message is now presented.

When the List option is selected, to avoid any unintended actions, all other options on the Ribbon Menu are disabled until List is Clicked again to return to the regular CSID Zones Form.

Central Station Monitoring

CSID Zones

The CSID Zones tab in the Subscriber Panels section of the Monitoring tab in the Edit View of the Subscriber Form has two columns which list the People To Call associated with this CSID (Account):

1.the Available to Call list which includes all Contacts in the Subscriber's Global Call List, and

2.the Call Order list which includes a list of the Contacts who are to be called when responding to Alarm Signals sent from this CSID, and the order in which those call attempts should be made.

 

By using the Global Call List capability, the Available to Call list may include quite a large number of available Contacts.

These Available to Call Contacts were previously displayed in the order in which they were originally entered.  This sorting method has become unworkable.

 

The solution was to sort the Available to Call list in groups:

a)S - The People To Call ("Contacts") entered specifically for this Subscriber;

b)A - The Alternate Contacts;

c)D - The Dealer Contacts.

 

Using these group codes (S, A, and D), the list of Contacts for each group is now displayed alphabetically with a Prefix added (e.g., S - abc..., A - abc..., D - abc...) representing the source of that Contact,

This provides an easier way to locate the desired Contact..

 

The Call Order list is not affected by this change - its order is determined by need, and set specifically for processing and responding to an Alarm Signal received for this CSID Zone.

Central Station Monitoring

Central Station Data

Notification List

CSID Zones

The Central Station Data section on the Monitoring sub-tab on the Subscriber Edit View has a new CSID Event Forwarding Check box field to implement the forwarding Signals reporting Events and Tests to the Master CSID Account, only when (and if) it has a Master CSID identified for that Account.

The Notification List on the CSID Zones Form now also supports an RS-232 message Type (in addition to Pager and Email).

Central Station Monitoring

MKMS CS - Central Station Monitoring Application - Login

To view the characters of the Password (when entered), Click the Eye Icon in the Password field before Clicking OK.

HelpFileMKMS-CSLogInDialog-EyeIcon

 

 


Third Edition UL® 1981 Standard

Chapter Links

Description of the Enhancement

Central Station Monitoring

STARK 5.1.35.XXXX UL® Version

This new version of MKMSCS.exe and its associated programs meet the Third Edition UL® 1981 Standard.

See the UL Installation Reference and UL Third Edition Installation Guide chapters, and the related links in those chapters for more information

Central Station Monitoring

UL Installation Reference

The information required for the proper installation of certain Micro Key Solutions applications, along with a Sybase SQL Anywhere Database application, that will be used by a UL® 1981 Listed Central Stations, are identified in this chapter (and its associated sub-chapters):

1)Micro Key Solutions Alarm Company Management & UL Monitoring Software Suite includes MKMS Version Number 5.1.35.8209 or later, and MKMSCS Version Number 5.1.35.7109  - each with a compile date one or after  after 10/01/2017;

2)MKMS and MKMSCS automation software uses the Windows® Operating System, Version 7 and later;

3)SPA Version 5.0.28.497 or later;

4)MKSSysStatus Version 1.2.0.3 or later;

5)MKSSounds Version 1.0.1.1 or later;

6)MKSCluster Version 3.1.0.4 or later;

7)MKSSysMon Version 1.0.1.33 or later;

8)WatchDog2 Version 1.0.0.3

9)Sybase SQL Anywhere database Version 16 or later.

Central Station Monitoring

Connection Manager

The MKS Connection Manager which is used to properly "link" your individual Company databases to the MKMS Sybase Anywhere Database Engine has been substantially upgraded for compliance with the Third Edition UL® 1981 Standard

Central Station Monitoring

UL Settings, Signal Processing & Reporting Procedures

These new UL Settings, Signal Processing & Reporting Procedures chapter (along with many other associated chapters which are identified with Links) will document certain Settings, and the Signal Processing & Reporting Procedures which are required when implementing the Third Edition UL® 1981 Standard, specifically for compliance with 20.8(a-q), and 24.3, Passwords.

Security & Access Management

Central Station Monitoring

Change Password

Add/Delete Users

When the UL® 1981 Version is Registered (i.e., Active), the Company Settings CheckULPasswordRestrictions option is set to True ("T") to comply with Section 6.2.6 relating to Password Restrictions in the Third Edition UL® 1981 Standard.

 

When the CheckULPasswordRestrictions option is set to True ("T") in Company Settings, the Password Requirement legend on the Change Password Form and the Add/Delete Users Form has been updated to more clearly identify those UL® requirements for password creation.

Central Station Monitoring

Company Settings

UL Stale Alarm Priority Cutoff - By default, the ULStaleAlarmPriorityCutoff option in Company Settings is set to Zero ("0").

For those Companies who are using the recommended Priority Levels for UL Certificated Alarm Systems documented in Section 11.1.5 (g) in the Third Edition UL® 1981 Standard, this should be set to seven ("7").

For those Companies who are using an optional set of Priority Levels allowed in Section 11.1.5 (g) in the Third Edition UL® 1981 Standard, this should be set to five ("5") assuming the the 2, 3, and 4 recommended Priority Levels have been combined (adjust accordingly).

 

Inactivity Disconnect - When the UL® 1981 Version is Registered (i.e., Active), this InactivityDisconnect option should be set to True ("T") to comply with Section 6.2.7 in the Third Edition UL® 1981 Standard - "Once communication of a session has been idle for a maximum of 15 minutes the session shall be automatically terminated."

When the InactivityDisconnect option should be set to True ("T"): after 15 minutes of inactivity by the current User, a Warning Message is displayed and if not acknowledged, the system will disconnect (log out of the database) and the User must Log In again tro continue to use the system.

If the InactivityDisconnect option is set to False ("F"), this Inactivity Disconnect feature will be turned off.

 

Check UL Password Restrictions - When the UL® 1981 Version is Registered (i.e., Active), this new The CheckULPasswordRestrictions option in Company Settings must be set to True ("T") to comply with Section 6.2.6 relating to Password Restrictions in the Third Edition UL® 1981 Standard.

If the CheckULPasswordRestrictions option is set to False ("F"), this Password Restrictions feature will be turned off.

 

A new Delete conformation message is displayed when a User attempts to Delete a CSID Zone record.

 

By default, the new ZoneTriggers option is set to False ("F") in the Company Settings Form

When the new Zone Triggers ("ZoneTriggers") option is set to True ("T"), it will add a Zone Triggers sub-tab to the CSID Zones Form.

If a Zone Trigger is defined, it will use its CSID, Zone, and Alarm Condition Code combination to cause command strings to be transmitted that can control various peripheral devices.

 

24 Hour Format - By default, in Company Settings the 24HouFormat option is set to False ("F") and so the current Time is displayed in the Status Bar for both MKMS and MKMSCS in usual 12 Hour format with am or pm appended to the Time, as appropriate.

However, the Time displayed on the MKMSCS Status Bar may be changed to a 24 Hour format by setting this 24HouFormat option to True("T").

Central Station Monitoring

Condition Code Resolutions

The new Condition Code Resolutions Form allows you to designate which Resolution Code may be used when completing certain types of Alarm Signals (i.e., Alarm Conditions).

Central Station Monitoring

Monitoring tab - Subscribers Form Edit View

The Monitoring tab - Subscribers Form Edit View now has a new:

Alarm History Icon on its Menu which displays the Alarm History Form for the currently selected Subscriber record.

Sub Dealer field to accommodate that new capability in the new Dealer Billing module.

Time Zone field with a Drop-Down Selection List containing all of the US and international Time Zones.

Cross Street field for identifying the nearest cross street

Central Station Monitoring

Docking Options

The new Docking Options Drop-Down Menu lists the choices the Operator has in managing which, and where the Special Info Grids will be displayed.

1.Pending Signals

2.Non Restored Signals

3.Two Way Voice

4.Close All (Information Grids)

5.Reopen Closed Windows

6.Restore to Dock Positions

Central Station Monitoring

Signal History - F4

When an Operator is Processing an Alarm in MKMSCS, she/he may Look Up the Alarm History for the Subscriber currently being displayed on the Signal Processing screen by Pressing F4.  This Signal History - F4 dialog has been substantially enhanced.

Central Station Monitoring

Alarm History Lookup

1)The Alarm History Lookup Form has added Subscriber (Name) and CSID to the Primary Signal History data grid's Header row within MKMS.

2)An Export option has been added to the Alarm History Lookup Form.

3)The Alarm History Lookup dialog now includes the full title of the UL® Classification (instead of UL Grade Number).

Central Station Monitoring

Sounds tab

Central Station Options tab

The Sounds tab within the Central Station Options tab of the User Options Form now supports identifying the Sounds for up to 20 Priority Levels (plus the Default sound).

Central Station Monitoring

Print Options

Central Station Options tab

The Print Options sub-tab within the Central Station Options tab of the User Options Form now has an additional field created to allow Users to specify a Monitoring Station which is displayed on the printed Alarm Certificate

Central Station Monitoring

Subscriber Options Menu

Alarms - The Alarm History dialog for the currently selected Subscriber may now be accessed from the Subscriber Options Menu and provides the same Alarm History dialog that is available when viewing the Monitoring tab on the Edit View of the Subscribers Form..

Central Station Monitoring

Communications Module

Notifications

This new Notifications sub-tab within the Monitoring tab provides the ability to identify and define one or more specific Alarm Conditions which - when received by SPA - are to be processed internally by sending a Predefined Message via an Email or Pager message (using the Communications Module) to a specific Person.

Central Station Monitoring

Dealer Breakdown Report

The revised Dealer Breakdown Report which provides a listing of each Dealer, their Accounts, related reporting and signal data, and summary information about each Dealer, now has a new options to Include Offline Accounts.

Central Station Monitoring

Create Mass Accounts

Account Templates

The Create Mass Accounts Form and Account Templates Forms has been updated with the current standard Navigation, Ribbon Menu systems, and also follows the selected Theme.

Central Station Monitoring

Dealer Users

The Dealers section of the Dealer Users dialog has been enhanced to allow the Dealer User to also be assigned to a Sub Dealer

The system assigned Telephone and Contact information will reflect the Dealer's unless a Sub Dealer is assigned, in which case that Telephone and Contact information will be the Sub Dealers'

Central Station Monitoring

Events (F10)

To allow for an easier way to re-set the Date and Time for Events, the "Start" and "End" fields in the Next Scheduled Event section have been enhanced with a dedicated Date field and a dedicated Time field for each ("Start" and "End") case.

Central Station Monitoring

Dealer Users

Online/Offline Report

A new Online/Offline Report Check box has been added to the Access section of the Dealer Users Form.

When this new Online/Offline Report box is Checked, the currently selected Dealer User may print/view the Online/Offline Report.

Central Station Monitoring

Company Settings

Alarm Stack

There is a new UseCIF option has been added to the Company Settings Grid which, by default, is set to False ("F")

When set to True ("T"), and a UseMasterCSIDForEvents field will be added internally in the Central Station table -  thus implementing a visible CSID Forwarding Events Check box in the Central Station section of the Monitoring tab, the Signals for Events and Tests will be forwarded to a previously identified Master CSID Account (see next discussion immediately below) when the new CSID Event Forwarding field is Checked.

 

There is a new MultipleAlarmStacks option has been added to the Company Settings Grid which, by default, is set to True ("T") thus allowing the Alarm Stack to be opened more than once in MKMSCS, if required

If the MultipleAlarmStacks option is set to False ("F"), only one Alarm Stack may be opened by a User.

 

There is a new AlarmStack.LimitGrid option in Company Settings which by default, is set to False ("F").

When the AlarmStack.LimitGrid option in Company Settings is set to True ("T"), the normal Filtering and Sorting capabilities - normally available in the Grid of the Alarm Stack  - are disabled.

Central Station Monitoring

Central Station Data

Notification List

CSID Zones

The Central Station Data section on the Monitoring sub-tab on the Subscriber Edit View has a new CSID Event Forwarding Check box field to implement the forwarding Signals reporting Events and Tests to the Master CSID Account, only when (and if) it has a Master CSID identified for that Account.

The Notification List on the CSID Zones Form now also supports an RS-232 message Type (in addition to Pager and Email).

Central Station Monitoring

Alarm Stack

The Alarm Stack has been revised with additional Columns of data available and a new History Icon that opens a Signal History sub-grid for the currently selected Signal listed in the Alarm Stack.

Added Third Edition UL® 1981 Standard Certificate types column

 

Central Station Monitoring

Alarm Stack Maintenance

The Alarm Stack Maintenance dialog has been updated to include:

Cannot purge Fire Alarms (ever)!

Purging from "Advanced" tab when choosing to ignore UL Accounts now works properly.

Central Station Monitoring

Signal Processing

Signal Processing - Expanded the Signal Priority level to 7 when evaluating the Investigator Arrival information.

Central Station Monitoring

Panel Zone Overrides

The Panel Zone Overrides Form again allows modification.

Central Station Monitoring

CSID Zones

If a duplicate Signal ID and Physical Zone combination is entered in the CSID Zones tab in the Subscriber Panels section, a much more informative error message is now presented.

When the List option is selected, to avoid any unintended actions, all other options on the Ribbon Menu are disabled until List is Clicked again to return to the regular CSID Zones Form.

Central Station Monitoring

CSID Zones

Notification List

Notification List - For Communication Module users, each CSID Zone (and Override) may have an additional Notification List for Paging and/or Emailing an Alarm or Event Signal Notification of this event, as needed.  

This Notification List will now be automatically sorted in Alphabetical Order based on the Employee's Name (as entered in People To Call)  

Central Station Monitoring

Email Modified Subscriber Now

The new Email Modified Subscriber Now is only in MKMS.

It opens the Email Modified Subscribers Now dialog which lists all Accounts that have been modified but not yet notified.  The User may:

Go to the Subscriber record

Print the list of all Accounts that have been modified but not yet notified

Export the list of all Accounts that have been modified but not yet notified

Choose the Accounts which are to be notified.

Email

Central Station Monitoring

CSID Zones

Notification List

Notification List - For Communication Module users, each CSID Zone (and Override) may have an additional Notification List for Paging and/or Emailing an Alarm or Event Signal Notification of this event, as needed.  

This Notification List will now be automatically sorted in Alphabetical Order based on the Employee's Name (as entered in People To Call)  

Central Station Monitoring

People To Call

Call List Verification

The Call Numbers section of the People To Call Form has been modified to accept up to 8 character telephone extensions

 

The Call List Verification report has been updated to accommodate 8 character People To Call telephone extensions, and the remaining People To Call data on this report was reformatted.

Central Station

Account Type

The Account Type Form has been updated (see immediately below) to include the Type field.  Using the Drop-Down Selection List provided for that field, Choose whether each Account Type should be classified as Commercial or Residential to accommodate this new MEW Factor reporting Option in the new UL Statistic Report (required for the MEW Factor's reporting requirements).

Central Station

UL Statistic Report

A new MEW Factor reporting Option has been added to the UL Statistic Report.

To accommodate this new MEW Factor reporting Option the Account Type Form has been updated (see above) to include a new Type field.

MEW Factor = (# of residential accounts) *0.333 + (# of commercial accounts with NO opening and closing events ) *1 + (# of commercial accounts with opening and closing events) *3).

Central Station

Signal Processing

While Signal Processing, when entering a Note, Pressing the Tab key will now automatically move the Cursor to the Save button.

Central Station

Signal Processing

There is now a Constraint for resizing the Signal Processing Form horizontally to prevent the User/Operator from hiding information on that Form.

Central Station

Signal Processing

In an interim version of MKMSCS, the Signal Processing Form was modified to "better handle" Screen Scaling changes.  It didn't.

With some cleanup, the system has reverted to the previious - more stable - Screen Scaling methodology.

Central Station

Signal Processing

Google Map® may now initially display either in "roadmap" (default) view, or in "satellite" view, as your Company's Central Station Manager prefers.

For those who want to use this feature, this feature requires the installation of a new Company Setting.  

INSERT INTO "DBA"."CompanySettings"("Section","SettingName","SettingValue") 

VALUES('Feature','DefaultMapType','roadmap')

To change the default map display to "satellite":

update dba.companysettings set settingvalue = 'satellite' 

where settingname = 'DefaultMapType'

Central Station

Signal Processing

To simplify a Signal Processing procedure, when the Note field is displayed and the Tab F key is pressed, the focus will more to the Save button.

Central Station

Sub Info (F2)

A new section has been added to the Sub Info (F2) Form which displays the Current Warranty Status in a Warranty Info box which includes the Contract Type, Warranty Status [Not In Warranty, In Warranty], and the Warranty Ends date for this Account.

 

 


Third Edition UL® 1981 Standard

Reports

Description

Central Station Monitoring

UL Signal Processing & Reporting Procedures

This new UL Signal Processing & Reporting Procedures chapter (along with many other associated chapters which are identified with Links) will document certain Settings, and the Signal Processing & Reporting Procedures which are required when implementing the Third Edition UL® 1981 Standard.

Central Station Monitoring

Alarm Ticket Report

The Alarm Ticket Report (redesigned and documented to comply with the Third Edition UL® 1981 Standard) is the detailed report of exactly what was done while an Operator processed an Alarm Signal.

Whenever an Alarm Ticket is printed while an Operator is Processing an Alarm Signal, an Alarm Ticket Printed entry is inserted into the Alarm Activity Report for that alarm event.

The Special Settings Requirements and Operator Procedures must be followed when Processing Alarm Signals with a Priority Level from 1 to 6 for those Subscribers with a UL® Classification assigned in the Central Station Data section.

The Alarm Ticket Report for a currently displayed alarm event may be (re-)printed at any time while that alarm event is still being Processed by selecting the Print Alarm Ticket option accessed using the Actions button

Central Station Monitoring

Insurance Information

Certificate of System Installation

Central Station Data

This Insurance Information Form was substantially revised to display the current list of UL Classifications (in a UL Class titled field instead of a UL Grade field); and provides the other required fields needed to properly produce an approved Alarm Certificate.

 

There are several other new fields which have been added and will display on the printed Alarm Certificate:

Install Date – This field will be auto populated when adding a new record on the Insurance Information Form.  It will be populated with the subscriber “Date Online” field when it’s populated; if not, it is left blank.  Users may change/modify this Date in the Insurance record, and it will not affect the “Date Online” field in the Monitoring section of the Subscriber Form.

Panel Type – This Drop-Down Selection List now contains entries from the “Installed Equipment” table that are flagged as a Panel.

Paid To – Indicates the Subscriber's payment status date.  This is a manual entry, and the User will have to populate it appropriately.

Signature – Allows the User to Select an Electronic Signature from the Signatures created in the Personal tab on Employees FormClicking the E-Signature Icon will present a Search Signature dialog for all Employees with an E-Signature entered.  The Icon is only available if the User has Access Rights to the Electronic Signature dialog.

Date Signed – Date of the Alarm Certificate. This is also a manual entry, and the User will have to populate it appropriately.

Security & Access Management

Central Station Monitoring

Employee Hired/Terminated

 

 

This is the new Employee Hired/Terminated report (documented to comply with the Third Edition UL® 1981 Standard) provides a list of the Company's Employees is displayed in a functioning Grid dialog with an Employee Trace Form Title:

It provides a list of the Employees - retrieved based on their Hire, Termination, or original Entry Date - that is displayed in Grid format and so may then be viewed, sorted, filtered, reconfigured, printed, emailed, and/or exported.

Central Station Monitoring

Signals While On Test

There is a new Signals While On Test report which is designed and documented to comply with the Third Edition UL® 1981 Standard and will report those signals that were received from a Subscriber (Account), and/or a Subscriber Panel (CSID) that occurred while an Account or CSID was On Test.

Central Station Monitoring

Operator Activity Crosstab

This new Operator Activity Crosstab report provides two views based on a Date Range filtered analysis of Operator Activity data.

Central Station Monitoring

Operator Activity New

This new Operator Activity New report provides two views based on a Date Range, and selected Alarm Code(s), and/or Operator(s) filtered analysis of Operator Activity data; and Grouped by the Operator, Alarm Condition, or Load Type (e.g., Stack, Auto, Related).

Central Station Monitoring

Operator Polling

This new Operator Polling report is based on a Date Range, and optionally selected Operator(s) and provides a filtered analysis of Operator Activity data to evaluate their work load and efficiency.

Central Station Monitoring

Accounts Without Email

There is a new Accounts Without Email report which is designed and documented to comply with the Third Edition UL® 1981 Standard and will list those Subscribers (Accounts) without an Email address entered in the Subscribers tab of the Subscribers Form: Edit View

The Accounts Without Email Report may be produced for All Accounts, or for UL® Accounts Only.

Central Station Monitoring

UL Statistics Report

This is the new UL Statistics Report which was specifically designed and documented to comply with the System Wide Reports Section 10.2.1 and 10.22 (a) - (g) of the Third Edition UL® 1981 Standard.

Central Station Monitoring

Users Login History Report

This is the new Users Login History Report (designed and documented to comply with the Third Edition UL® 1981 Standard) which will list those Employees who have attempted to, or successfully Logged Into the MKMS database (mkmsdefault.db).

Central Station Monitoring

Alarm Activity Report

This report was revised to display the full title of the UL® Classification (instead of UL Grade Number).

Central Station Monitoring

Subscriber Information Forms

The Subscriber Information Forms report now includes the full title of the UL® Classification (instead of UL Grade Number).

Central Station Monitoring

Dealer Breakdown Report

The revised Dealer Breakdown Report which provides a listing of each Dealer, their Accounts, related reporting and signal data, and summary information about each Dealer, now has a new options to Include Offline Accounts.

 

 

 

 

MKMSCS 5.1.35.7143 & MKMS 5.1.35.8252

 